Description
- Is Smart Device: YES
- is_customized: Yes
- Output Current: 1/27A
- Output Frequency: 50Hz 60Hz
- Output Power: 1 – 200KW
- Output Type: SINGLE
- Weight: 15kg
- Size: 537*390*130mm
- Model Number: AN-SCI-MAX
- Brand Name: ANERN
- Origin: Mainland China
- Certification: CE,RoHS
- Max Panel Input Voltage: 450V/500V
- Battery Type: Lifepo4 Batteries, Lithium Batterie
- Nominal Output Voltage: 220V 230V 240V
- Grid Tie Inverter: MPPT Solar Inverter
- Hybrid Solar Inverter 48V: Grid-tie Hybrid Inverter Charger
8200W 10200W Off Grid Solar Inverter Hybrid MPPT 160A 230V Pure Sine Wave Hybrid Inverter DC 48V for Battery Charger
Features:
â—† Pure Sine Wave Solar Hybrid Inverter;
â—† Be able to run without battery;
â—† One-key restoring to factory default settings;
â—† PV automatically activates lithium batteries;
 ◆ Bulit-in 160A MPPT solar controller(for 10.2KW),
140A(for 7.2KW);"
â—† Max 7500W & 10800W solar input power respectively;
â—† Wide PV input voltage range (90-450VDC);
â—† Built-in anti-dusk kit for harsh environment.
â—† Smart battery charge design to maximize battery lifespan
â—† Dual PV Input & AC output;
â—† WIFI available for IOS and Android systems.
 ◆ Connectable battery type:Lead-acid/Gel/AGM/Lithium Iron Phosphate(LiFePo4)/Lithium battery
10200W:Dual PV Input(Dual MPPT),Dual AC Output(Only 10200W models dual MPPT)
Model |
SCI-MAX-8200 |
SCI-MAX-10200 |
RATED POWER |
8200W
|
10200W |
Maximum PV Input Power |
8200W
|
10800W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
MPPT DC Voltage Range |
90-450VDC |
Number of MPPT Trackers/Maximum
Input Current
|
1/27A
|
2/18A
|
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
Nominal Output Current
|
35.6A
|
44.3A
|
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
8200W
|
10200W |
Maximum Main Load |
8200W
|
10200W |
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V) |
2733W
|
3400W |
Main Load Cut Off Voltage |
44VDC
|
44VDC |
Main Load Return Voltage |
48VDC
|
48VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
Maximum AC Input Current
|
40A
|
50A
|
Nominal Operating Frequency
|
50/60Hz
|
Surge Power
|
16400W
|
20400W
|
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
48VDC
|
48VDC |
Maximum Charging Current(Solar to AC) |
160A
|
160A |
Maximum AC Charging Current |
140A
|
160A |
GENERAL |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C – 50°C |
Storage Temperature |
–15°C – 60°C |
FAQ:
Q:Whether it can be connected to the grid?
A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)
Q: Is this a on grid-tied inverter? Can it be output to utility?
A: YES. It is a hybrid inverter that can be both off-grid and on-grid connected
Q: Is it possible to use PV, battery, grid supply at the same time?
A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
Q: Can inverters be connected in series or parallel?
A: NO.
Q: Can the utility be used to power the inverter when there is no sun?
A: YES.
Q: How to choose the power of the inverter according to the household appliances?
A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
Q: How many solar panels need to be connected?
A: In order to start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, The maximum does not exceed 500V.
Inverter Use Notice
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.
About Us
Anern,has been dedicated in bringing clean energy to each country,and help people all around the world to enjoy the facility and convenience brought by clean energy.
12 years experience in solar energy and led lighting industry.providing service to over 200 countries and areas globally.having developed over 3,000 solar energy projects worldwide.
Anern has successfully completed hundreds of mega government projects in the past 12 years
Anern is headquartered in guangzhou,which is one of the most important Chinese Central Cities.
In addition to headquarter in Guangzhou,Anern has also set up factories and offices in Shenzhen,Zhongshan and Zhejiang
Reviews
There are no reviews yet.